Configuring Entry & Exit IXM Devices with single door

Applies to

TITANTOUCH 2SENSE 2MERGEMYCROMERGE CR
All DevicesAll DevicesAll DevicesAll DevicesAll DevicesAll Devices

Description

This process will allow configuring two different IXM Device(s) with a single door lock or door strike, one as an Entry Device and one as an Exit Device.

Entry Device wire connection & settings

  • Entry device will be considered as a primary device and will be controlling the door lock. Configure device with door lock as per the following diagram (Available in INGUIDE). The following diagram shows connection between device & NO (Normally Open) door lock.
  • In IXM WEB click CONFIG tile >> Door Access Control app.
  • Toggle “Door Access Control” to ON  activate the Door Access Control settings & Request-to-Exit mode should be set to “Normally Open”.
  • Click Apply to save the settings to the IXM device.

Exit Device wire connection & settings

  • The Exit device will be considered as secondary device and will send command to entry device to open the door. Connect exit device with entry device as per following diagram.
  • In IXM WEB click CONFIG tile >> Door Access Controlapp.
  • Toggle “Door Access Control” to OFFif it is ON. By default is should be OFF.
  • Click CONFIG tile >> Input/Output (Output for MERGE) app.
  • Select Authentication Success & Duress finger event for SP Output 1.
  • Click Apply to save the settings to the IXM device.